GAC ALR series

GAC’s ALR electronic actuators are an integral part of an electronically governed system. They are designed to receive instructed signals from the magnetic pickup and compare those to desired signals, alternating the speed as appropriate.

GAC ALR Electronic Actuators

The GAC ALR Electronic Actuators allow for accurate speed control and fast response to load changes

IPU stock the entire range of GAC ALR electronic actuators and they are compatible with the following engine types:

ALR160-S04 Shibaura N840 & Caterpillar variants
ALN190-F04 Farymann 18 W Series
ALR190-I03 Isuzu 3L and 4L Series
ALR190-K04 Kubota 05, V and V3 Series
ALR190-K24 Kubota M03
ALR190-KV2403 Kubota V2403
ALR190-KV3307 Kubota V3307
ALR190-KV3600T Kubota V3600
ALR190-M04 Mitsubishi L Series and S Series
ALR190-P04 Perkins 404 Series
ALR190-P403 Perkins 403 Series
ALR190-Y04 Yanmar TNV Series and Isuzu C Series

GAC’s ALR electronic actuators are constructed to a high quality military standard, and are suitable for high temperature operation. Not only that, but they’re built with linear ball bearings instead of plastic bushes, meaning they’re a lot less likely to wear.

The lifetime of the GAC ALR Series actuators is 20 million cycles – making them perfect for variable speed control.

Download our datasheet to find out which of the ALR electronic actuators you need with your particular engine. It will also list corresponding engine governors and magnetic pickup sensors that will complete your electronic governing system.

 

Why should I switch to electronic governing?

There are many other benefits in making the switch from mechanical governing to electronic. With electronic governing:

  • Gensets and engines can maintain a constant frequency whatever the load. Sensitive electronic equipment is protected against damaging fluctuations such as droop or overshoot. This is especially important in IT and healthcare.
  • Engines respond faster to load changes – as much as 200 times faster than engines with mechanical governing.
  • You improve your fuel economy because an electronic governor accurately sets the engine’s throttle to match the load. This means if you need 50% power it will open the throttle to 50%. Mechanical throttles are either open or closed – there is no in-between.That reduces your bills and your environmental footprint and makes electronic governing ideal for non-genset applications.
  • You avoid the massive disruption of installing a new engine from scratch – the upgrade is simple and quick.

Upgrading from mechanical governing to electronic governing is simple and quick so is ideal for retrofitting. The actuator takes less than 5 minutes to install as there are no complicated linkages.

 

Video – Simple ALR electronic actuators installation

This video shows just how simple it is to install a GAC ALR actuator onto your engine. In less than 90 seconds, you’ll see the original solenoid removed and the new actuator attached and ready to go.

Specifications

GAC ALR 160S GAC ALN 190F GAC ALR 190I GAC ALR 190K GAC ALR 190M GAC ALR 190P GAC ALR 190Y
Operating Stroke 0.51” (13.0mm) 0.9” (22.86mm) 0.55” (14.0 mm) 0.49” (12.5mm) 0.54” (13.9mm) 0.42” (10.4 mm) 0.34“ (9.0 mm)
Response time 35 msec 35 msec 35 msec 35 msec  35 msec 35 msec 35 msec
Operating Voltage 12 or 24VDC 12 or 24VDC 12 or 24VDC 12 or 24VDC 12 or 24VDC 12 or 24VDC 12 or 24VDC
Nominal Operating Current 4.8 A @ 12VDC

2.4 A @ 24VDC

1.6 A @ 12VDC

0.8 A @ 24VDC

3.2 A @ 12VDC

1.6 A @ 24VDC

3.2 A @ 12VDC

1.6 A @ 24VDC

3.2 A @ 12VDC

1.6 A @ 24VDC

3.2 A @ 12VDC

1.6 A @ 24VDC

3.2 A @ 12VDC

1.6 A @ 24VDC

Maximum Continuous Current 7.5 A @ 12VDC

3.8 A @ 24VDC

3.8 A @ 12VDC

1.8 A @ 24VDC

5.0 A @ 12VDC

2.5 A @ 24VDC

5.0 A @ 12VDC

2.5 A @ 24VDC

5.0 A @ 12VDC

2.5 A @ 24VDC

5.0 A @ 12VDC

2.5 A @ 24VDC

5.0 A @ 12VDC

2.5 A @ 24VDC

Coil Resistance (12) 1.6 ± 0.2 Ohms

(24) 6.4 ± 0.2 Ohms

(12) 1.8 ± 0.2 Ohms

(24) 7.3 ± 0.2 Ohms

(12) 1.8 ± 0.2 Ohms

(24) 7.2 ± 0.2 Ohms

(12) 1.8 ± 0.2 Ohms

(24) 7.2 ± 0.2 Ohms

(12) 1.8 ± 0.2 Ohms

(24) 7.2 ± 0.2 Ohms

(12) 1.8 ± 0.2 Ohms

(24) 7.2 ± 0.2 Ohms

(12) 1.8 ± 0.2 Ohms

(24) 7.2 ± 0.2 Ohms

Connection (0.8 mm²) leads (0.8 mm²) leads (0.8 mm²) leads (0.8 mm²) leads (0.8 mm²) leads (0.8 mm²) leads (0.8 mm²) leads
Operating Temperature -40 to 200°F

(-40 to 95 °C)

-40 to 200°F

(-40 to 95 °C)

-40 to 200°F

(-40 to 95 °C)

-40 to 200°F

(-40 to 95 °C)

-40 to 200°F

(-40 to 95 °C)

-40 to 200°F

(-40 to 95 °C)

-40 to 200°F

(-40 to 95 °C)

Relative Humidity Up to 100% Up to 100% Up to 100% Up to 100% Up to 100% Up to 100% Up to 100%
Vibration 25 to 100 Hz, +/- 4g 20 to 100 Hz, +/- 4g 25 to 100 Hz, +/- 4g 25 to 100 Hz, +/- 4g 25 to 100 Hz, +/- 4g 25 to 100 Hz, +/- 4g 25 to 100 Hz, +/- 4g
Shock 20 g, 11 msec 20 g, 11 msec. 20 g, 11 msec. 20 g, 11 msec. 20 g, 11 msec. 20 g, 11 msec. 20 g, 11 msec.
All surface finishes Fungus Proof and Corrosion Resistant Fungus Proof and Corrosion Resistant Fungus Proof and Corrosion Resistant Fungus Proof and Corrosion Resistant  Fungus Proof and Corrosion Resistant Fungus Proof and Corrosion Resistant Fungus Proof and Corrosion Resistant
Sealing Oil, water, and dust resistant Oil, water, and dust resistant Oil, water, and dust resistant Oil, water, and dust resistant Oil, water, and dust resistant Oil, water, and dust resistant Oil, water, and dust resistant
Dimensions (mm) 118.1 x 40 97.6 x 48.2 103.6 x 48.2 103 x 48.2 115.6 x 48.2 97.8 x 48.2 110.4 x 48.2
Weight 1.3lb (0.59 kg) 1.3lb (0.59 kg) 1.3lb (0.59 kg) 1.3lb (0.59 kg) 1.3lb (0.59 kg) 1.3lb (0.59 kg) 1.3lb (0.59 kg)

 

GAC Product Selector

Find out what actuator, governor and magnetic pickup you need for your engine by using our simple product selector.