Datakom DKG705

The Datakom DKG705 is an Automatic Mains Failure unit for genset control and mains paralleling, with built in G59 protection.

Main features of the Datakom DKG705:

  • Automatic mains failure with genset control and protection
  • J1939 engine monitoring and control port
  • Remote Start operation capability
  • True RMS measurements
  • Complete genset power measurements
  • Complete mains power measurements
  • Synchroscope
  • Governor and AVR control interface
  • KW/KVAr load control
  • No break transfer and load test
  • Soft transfer with ramp control
  • Single set parallel with mains
  • Peak lopping (peak shaving)
  • Dual Genset synchronization and parallel with mains
  • G-59 mains protections
  • Dual language support
  • Battery backed-up real time clock
  • Daily, weekly, monthly exerciser
  • Weekly operation schedule programs
  • Periodic maintenance request display
  • Event logging
  • Statistical counters
  • Upgrade software downloadable from serial port
  • Output expansion capability
  • Serial RS-232 data output
  • Free MS-Windows remote monitoring SW with modem networking
  • GSM-SMS sending in case of alarm
  • Modem call in case of alarm
  • MODBUS communication
  • Field programmable
  • Configurable analogue inputs: 4
  • Configurable digital inputs: 8
  • Configurable relay outputs: 7
  • Sealed front panel, IP65 protection
  • Dimensions: 144x192x49mm

Optional features:

  • Internal Modem
  • External DC voltage measurement
  • External DC voltage based operation

 

The DKG-705 is a comprehensive AMF unit for a single generating set operating in standby or parallel with mains modes.

The DKG-705 unit is able to transfer the load between mains and genset in 4 different ways:

  • Transfer with interruption – there will be a power interruption period duration during the transfer
  • No break transfer without synchronization – transfer will be made without power interruption. The unit waits until mains and generator phases match and makes a quick transfer.
  • No break transfer with synchronization (available only with “full” version) – transfer will be made without power interruption. The unit operates the governor and AVR control outputs to synchronize the generator with the mains and makes a quick transfer.
  • Soft transfer (available only with “full” version): transfer will be made without power interruption. The unit operates the governor and AVR control outputs to synchronize the generator with the mains and makes a smooth ramped transfer.